Panasonic AW-RP50N When setting the IP addresses for the first time, Connections

Models: AW-RP50N

1 82
Download 82 pages 17 Kb
Page 72
Image 72
￿￿When setting the IP addresses for the first time

Connections

￿￿Setting the IP addresses automatically (auto IP setting)

When “Auto IP setting” is initiated, the IP addresses are set automatically for the remote cameras and the switcher which are connected within the same subnet.

The IP addresses can be set for up to 100 remote cameras and one switcher.

Note

Contention in the IP addresses may arise when a device other than a remote camera or switcher has been connected within the same subnet.

Connect only devices which are covered by the “Auto IP setting” within the same subnet.

￿￿When setting the IP addresses for the first time

The IP addresses are set while the remote cameras, switcher and unit are at their factory settings.

1Connect the remote cameras, switcher and unit to the network within the same subnet.

192.168.0.10

￿192.168.0.22

192.168.0.10

192.168.0.10

￿ 192.168.0.23

￿ 192.168.0.21

 

192.168.0.20

192.168.0.30

￿ 192.168.0.24

 

2 On the [SYSTEM] menu, select [AUTO SET

IP], and display [AUTO SETUP]. Then select RENEW, and press the F2 dial.

1.AUTO SETUP RENEW 2 On the [SYSTEM] menu, select [AUTO SET

The total number of all the remote cameras and switchers currently connected as well as the total number of the remote cameras and switchers scheduled to be added —the units that are the target of “Auto IP setting”— are displayed on the LCD panel.

C:20/50 S:1/1

YES Manual background

C:20/50

Manual background Number of units connected within the same network

Remote cameras and switchers scheduled to be added

C: Remote camera, S: Switcher

25