 OA tally setting

Linking the unit with the switcher

6.TALLY_IP  Off OA tally setting

From the [SETUP] menu, select [SW LINK] and display [TALLY_IP].Then set On or Off.

6.TALLY_IP  PAN/TILT lever control setting Off 7.P/T LEVER

When “On” is selected as the item setting, the unit receives the tally information (tally ON/OFF) sent periodically from the switcher through the network, and it sends the ON or OFF instruction to the remote cameras in which changes have occurred.

[Concerning the tally information transferred through the network]

After receiving the tally information (Input1 to Input5) from the switcher through the network, the unit sends the ON or OFF instruction to the remote cameras.

Based on the relationship between the image output (remote camera) and image input (switcher) which have been set using the unit’s menu, the remote camera to which the

tally instruction is sent in response to the tally information received from the switcher is identified, the tally indicator of that remote camera is lighted in red, and the tally ON instruction is sent to the remote camera.

The Tally ON instruction is also sent to the remote cameras which are not in the selected camera group.

The following tally-related settings can be established using the menu.

￿￿Enabling/disabling the tally information instructions sent over the network

If only the tally information from GPI is to be enabled, from the [SETUP] menu select [SW LINK], set [TALLY-IP] to Off, and disable the tally information instructions sent over the network.

￿￿Enabling/disabling the tally ON instructions sent to the remote cameras

From the [CAMERA] menu, select [TALLY] and display [TALLY]. Then set enable or disable for the tally ON instructions to be sent to the remote cameras in response to the tally requests from the GPI and over the network.

Self PAN/TILT lever control setting

This setting makes it possible to use the unit’s PAN/TILT lever as the switcher’s control lever.

From the [SETUP] menu, select [SW LINK] and display [CAMSEL]. Then set Self/SW.

7.P/T LEVER

Self PAN/TILT lever: X, Y speed

AW-HS50

Input1

 

IP

RP50CAMNo

 

 

Input1

CAM1

 

 

Input2

CAM2

 

 

Input3

CAM3

 

 

Input4

CAM4

 

 

Input5

CAM5

 

 

 

 

 

AW-RP50

Input3

GPI Input

TALLY

CAM 1 2 3 4 5

Group 1

Group 2

1 2 3 4 5

When “Self” has been selected as the setting, the unit’s PAN/TILT lever is used as the lever for operating the pan and tilt functions of the remote cameras.

When “SW” has been selected, the following information is sent to the switcher.

PAN/TILT lever: X, Y speed

ZOOM button: Size speed

In response to inputs 1 to 5 from GPI Input, tally indicators CAM1 to CAM5 are lighted in red, and the tally ON instruction is sent to the remote cameras concerned. Only CAM1 to CAM5 serve as the GPI Input tally.This means that when a camera group other than No.1 is selected, the tally indicators will go off.