4.2. Troubleshooting

Please take note of the following two points with regard to troubleshooting:

1.Know-how of diagnosis upon occurrence of heavy troubles, e.g. Set cannot be turned ON , Set fails to start , No display on screen , etc.

2.Explanation of each trouble, mainly symptom of trouble in operation.

Flow Chart

START

START

Pay attention to the following points when in pursuit of the cause of a troubleshooting.

1.Peripheral apparatus connected with the set should all be removed before operation check.

2.Make sure that cables, boards, etc. are not coming off, and recheck the contact condition.

Set cannot be supplied with current. Power lamp fails to light up.

Dark display on screen.

Screen fails to display.

ACNG Adaptor/Battery

Output voltage

 

OK

Power lamp

NO

check

YES

 

Inverter board

NG

 

 

OK

LCD back

NO

 

light lighting

 

Replace AC Adaptor/Battery

Check contact condition of power input terminal. Replace if defective.

Check Power SW. Replace if defective.

Replace inverter board.

Check inverter cable continuity. Replace if defective

Replace LCD back light.

Failure in starting

YES

LCD unit

NG

 

 

 

 

 

Replace LCD unit.

 

check

 

 

 

 

 

OK

 

 

 

 

 

BIOS operation

NO

 

 

Replace main board (Check fuse at power source).

check

 

 

 

 

 

 

 

 

 

 

Not displayed properly on screen.

YES

 

 

Result of

NG

Refer to POST

 

 

 

 

 

 

 

 

 

 

 

 

Replace main board.

 

 

 

 

POST

 

 

 

 

 

 

 

error code table.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

Set-up utility

 

 

 

 

 

 

Heavy trouble e.g.,

 

 

Replace main board.

 

 

 

 

starting

 

 

 

 

 

 

 

 

 

 

Set cannot be turned

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

ON , Set fails to start ,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No display on

 

 

Return set-up utility setpoint to the state of delivery from factory .

 

 

screen , etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Check HDD cable connection and continuity.

 

 

 

 

HDD access

 

 

Replace if defective.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace HDD & Reinstall.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

Replace main board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main board

NG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace main board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Some or all keys cannot be input.

OK

Make sure of contact of K/B connector in use. Replace keyboard or main board.

Each kind of trouble in operation.

CD CALL not practicable.

Starts but operates unstably.

TroubleNO symptoms on some

of CD

YES

Replace main board.

Reinstall HDD.

Replace main board.

STARTEND

Check if there are any flaws on CD media. Since flaws may appear on specific media, CD media can be defective.

4-2

Page 14
Image 14
Panasonic CF-30KTPAXxM service manual Troubleshooting