SETTING THE TIMER

1. How to set the present time

(Example) To set to 9:10 pm.

 

Operation

Indication

 

 

 

1.

Press the SET button three

The time indication alone

 

times.

flashes.

2.

• Press the HH button until

The display will flash for 10 sec.

 

PM 9 is displayed.

and automatically stop flashing

 

• Press the MM button until

except for the “ : ” symbol.

 

10 is displayed.

 

 

 

 

2. How to set the OFF time

(Example) To stop the air conditioner at 11:30 pm.

 

OFF TIME

 

Present time

 

 

 

 

 

 

Operation

 

Indication

 

 

 

 

 

1.

Press the SET button twice.

The timer

indication alone

 

 

flashes and the previous set-

 

 

time is only displayed.

 

2.

• Press the HH button until

The display will change

 

 

PM 11 is displayed.

automatically back to show the

 

• Press the MM button until

present time after about 10 sec.

 

30 is displayed.

 

 

 

3.

Press the TIMER SELECT

The present time and

are

 

button twice to set OFF time.

displayed.

 

 

 

 

 

 

 

To cancel the setting, press the TIMER SELECT button twice.

3. How to set the ON time

(Example) To start operation at 7:10 am.

 

ON TIME

 

 

Present time

 

 

 

 

 

 

 

 

Operation

 

Indication

 

 

 

 

 

 

 

 

1.

Press the SET button once.

The timer

 

indication alone

 

 

 

flashes and the previous set-

 

 

time is only displayed.

 

 

2.

• Press the HH button until

The display will change

 

 

 

AM 7 is displayed.

automatically back to show the

 

• Press the MM button until

present time after about 10 sec.

 

10 is displayed.

 

 

 

 

 

3.

Press the TIMER SELECT

The present time and

 

are

 

 

button once to set ON time.

displayed.

 

 

 

 

 

 

 

 

 

 

 

To cancel the setting, press the TIMER SELECT button three times.

4. How to set daily ON/OFF repeat timer

(Example) To start operation at 7:10 am. and stop the air conditioner at 11:30 pm.

Present time

OFF TIME

ON TIME

 

 

Programmed

 

 

 

daily ON / OFF

9:10 pm.

7:10 am.

11:30 pm.

Present time

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

Indication

 

 

 

 

 

Set the timer ON/OFF times as

The present time PM 9:10 and

shown in 2 and 3.

 

 

 

are displayed.

 

 

 

 

 

 

 

 

 

 

 

 

To cancel the setting, press the TIMER SELECT button once.

NOTE

You can check the timer ON/OFF times after you have set them by pressing the SET button.

5. Backup function

Even if the main power supply to the unit is turned off, the remote controller will store the previous settings in its internal memory for up to 8 hours. If the power is not turned back on within 8 hours, the previous settings will be lost. In this case, the mode settings must be reset by the user.

9

Page 127
Image 127
Panasonic CS-KS18B4UW & CZ-18BT1U, CU-KS18NKUA, CU-KS12NK1A Programmed, Daily on / OFF, 910 pm 710 am 1130 pm Present time

CS-KS18B4UW & CZ-18BT1U, CS-KS12NB41 & CZ-18BT1U, CU-KS12NK1A, CU-KS18NKUA specifications

Panasonic has long been a reputable name in the HVAC (Heating, Ventilation, and Air Conditioning) industry, continuously innovating to provide efficient and sustainable solutions. Among their latest offerings, the CU-KS18NKUA, CS-KS18B4UW, CU-KS12NK1A, and CS-KS12NB41 split systems stand out for their advanced features and technologies designed to enhance user comfort while minimizing environmental impact.

The CU-KS18NKUA and CS-KS18B4UW units are high-capacity air conditioning systems that cater to larger spaces. One of their defining features is the inverter technology, which allows the compressor to adjust its speed according to the demand, leading to significant energy savings. The units operate quietly, contributing to a peaceful environment whether in homes or offices. Furthermore, the super-efficient energy consumption aligns with modern sustainability practices, reducing users' carbon footprints.

The advanced R32 refrigerant used in these systems is another highlight. R32 is known for its lower global warming potential compared to traditional refrigerants, making it an eco-friendly choice. These models are equipped with a powerful cooling capability while maintaining a compact and sleek design, seamlessly integrating into various interior styles.

In terms of indoor air quality, both models incorporate a multi-stage filtration system. This system effectively filters out dust, allergens, and harmful particles, ensuring cleaner indoor air. Additionally, the nanoe-G technology helps in deodorizing and purifying the air, enhancing the overall comfort and health of the environment.

The CU-KS12NK1A and CS-KS12NB41 models cater to smaller rooms but do not compromise on performance. They share similar inverter technology and energy-efficient characteristics as their larger counterparts, ensuring that users can enjoy a comfortable climate in a smaller footprint.

With an emphasis on user-friendly design, all these models come with intuitive remote controls, allowing for easy temperature adjustments and scheduling. Some units even offer Wi-Fi connectivity for remote access and monitoring via smartphone apps.

The CZ-18BT1U, often paired with these outdoor units, serves as an innovative air conditioning solution that supports energy efficiency and provides reliable cooling performance.

Overall, the Panasonic CU-KS and CS series units are ideal for consumers looking for modern, efficient, and environmentally friendly air conditioning solutions. Their combination of advanced technologies, user-centric design, and eco-conscious operation set them apart in the competitive HVAC market.