Panasonic CS-KS18B4UW & CZ-18BT1U Service Valve Connections, Table, Mounting on a Wall, Fig

Models: CS-KS18B4UW & CZ-18BT1U CS-KS12NB41 & CZ-18BT1U CU-KS12NK1A CU-KS18NKUA

1 136
Download 136 pages 28.94 Kb
Page 115
Image 115
Service Valve Connections

Service Valve Connections

a)Temporary connection:

Screw in 3 – 5 turns by hand. (Fig. 34)

b)To fasten the flare nuts, apply specified torque as Table 8 and Fig. 35.

Table 8

Tube Dia.

Nut

Tightening Torque

 

 

 

1/4" (6.35 mm)

21/32" (17 mm)

Approx. 120 – 160 lbs·in (140 – 180 kgf·cm)

 

 

 

3/8" (9.52 mm)

7/8" (22 mm)

Approx. 300 – 360 lbs·in (340 – 420 kgf·cm)

 

 

 

1/2" (12.70 mm)

1-1/32" (26 mm)

Approx. 430 – 480 lbs·in (490 – 550 kgf·cm)

 

 

 

5/8" (15.88 mm)

1-5/32" (29 mm)

Approx. 590 – 710 lbs·in (680 – 820 kgf·cm)

 

 

 

7. Remote Controller Installation Position

The remote controller can be operated from either a non-fixed position or a wall-mounted position.

To ensure that the air conditioner operates correctly, do not install the remote controller in the following places:

In direct sunlight

Behind a curtain or other place where it is covered

More than 26' (8 m) away from the air conditioner

In the path of the air conditioner’s airstream

Where it may become extremely hot or cold

Where it may be subject to electrical or magnetic interference

Where there is an obstacle between the remote con- troller and the air conditioner (since a check signal is sent from the remote controller every 5 minutes)

7-1. Mounting on a Wall

Before mounting the remote controller, press the ON/OFF operation button at the mounting location to make sure that the air conditioner operates from that location. The indoor unit should make a beeping sound to indicate that it has received the signal.

Remote control holder 7. Remote Controller Installation Position

7-1. Mounting on a Wall Press

Set in place

Mounting screws

5/32 Remote control holder 5/8" (4 Mounting screws 16 mm) (included)

Fig. 34

Torque wrench

Fig. 35

CAUTION

Be sure to tighten the flare nut

using the prescribed torque. If the

 

 

 

nut is over-tightened, refrigerant

 

leakage may occur.

Rear side

Hole

To prevent loss of the remote controller, you can connect the remote controller to the holder by passing a string through the remote controller and attachment hole.

To take out the remote controller, pull it forward.

Fig. 36

27