1. How to set the present time

(Example) To set to 10:30 pm.

 

Operation

Indication

 

 

 

1.

Press the CLOCK button

The time indication alone

 

once if the time indicator is

flashes.

 

not flashing.

 

2.

Press the Advance, Return

The time can be set in 1-minute

 

( , ) button until PM 10:30

increments. Holding down the

 

is displayed.

button advances the time rapidly

 

 

in 10-minute increments.

3.

Press the CLOCK button

This completes the setting of the

 

again.

current time.

 

 

 

2. How to set the OFF time

(Example) To stop the air conditioner at 11:00 am.

 

Operation

Indication

 

 

 

 

1.

Press the OFF TIME setting

The timer

indication is

 

button once.

displayed, and the present OFF

 

 

time is shown.

 

2.

Press the Advance, Return

The timer

indication

 

( , ) button until AM 11:00

blinks.

 

 

is displayed.

The time can be set in 10-minute

 

 

increments. Holding down the

 

 

button advances the time rapidly

 

 

in 10-minute increments.

3.

Wait a few seconds, and then

The timer

indication

 

the setting is complete.

stops blinking and the present

 

 

time is displayed.

 

 

 

 

 

3. How to set the ON time

(Example) To start operation at 7:10 am.

 

Operation

Indication

 

 

 

 

1.

Press the ON TIME setting

The timer

indication is

 

button once.

displayed, and the present ON

 

 

time is shown.

 

2.

Press the Advance, Return

The timer

indication

 

( , ) button until AM 7:10

blinks.

 

 

is displayed.

The time can be set in 10-minute

 

 

increments. Holding down the

 

 

button advances the time rapidly

 

 

in 10-minute increments.

3.

Wait a few seconds, and then

The timer

indication

 

the setting is complete.

stops blinking and the present

 

 

time is displayed.

 

 

 

 

 

4. How to set daily ON/OFF repeat timer

(Example) To start operation at 7:10 am. and stop the air conditioner at 11:00 am.

10:30 pm.

7:10 am.

11:00 am.

Present time

ON

OFF

 

 

 

 

 

 

 

 

 

 

Operation

Indication

 

 

1. Set the timer ON/OFF times

The present time 10:30 pm. and

as shown in 2-1, 2, 3 and 3-1,

are displayed.

2, 3.

 

 

 

NOTE

The ON/OFF combination timer uses the current time as the reference, and it is activated starting from whichever set time comes first.

With the ON/OFF combination timer, the settings are repeated every day.

You can check the timer ON/OFF times after you have set them by pressing the ON TIME and OFF TIME setting buttons.

To cancel a timer program

Press the CANCEL button.

When either an ON or OFF timer is to be canceled, press the button corresponding to the timer whose program is to be canceled, and then press the CANCEL button.

NOTE

The airflow direction, fan speed and temperature setting can be changed after a timer program has been set even when the unit is stopped. Even when operation is stopped during an ON timer program, the unit will start operating when the set time is reached provided that the program is not canceled.

When the ON timer and OFF timer are set to the same time, the timer operates as if it is turned off.

11

Page 81
Image 81
Panasonic CU-KS12NK1A, CU-KS18NKUA Operation Indication, 1030 pm 710 am 1100 am Present time, To cancel a timer program

CS-KS18B4UW & CZ-18BT1U, CS-KS12NB41 & CZ-18BT1U, CU-KS12NK1A, CU-KS18NKUA specifications

Panasonic has long been a reputable name in the HVAC (Heating, Ventilation, and Air Conditioning) industry, continuously innovating to provide efficient and sustainable solutions. Among their latest offerings, the CU-KS18NKUA, CS-KS18B4UW, CU-KS12NK1A, and CS-KS12NB41 split systems stand out for their advanced features and technologies designed to enhance user comfort while minimizing environmental impact.

The CU-KS18NKUA and CS-KS18B4UW units are high-capacity air conditioning systems that cater to larger spaces. One of their defining features is the inverter technology, which allows the compressor to adjust its speed according to the demand, leading to significant energy savings. The units operate quietly, contributing to a peaceful environment whether in homes or offices. Furthermore, the super-efficient energy consumption aligns with modern sustainability practices, reducing users' carbon footprints.

The advanced R32 refrigerant used in these systems is another highlight. R32 is known for its lower global warming potential compared to traditional refrigerants, making it an eco-friendly choice. These models are equipped with a powerful cooling capability while maintaining a compact and sleek design, seamlessly integrating into various interior styles.

In terms of indoor air quality, both models incorporate a multi-stage filtration system. This system effectively filters out dust, allergens, and harmful particles, ensuring cleaner indoor air. Additionally, the nanoe-G technology helps in deodorizing and purifying the air, enhancing the overall comfort and health of the environment.

The CU-KS12NK1A and CS-KS12NB41 models cater to smaller rooms but do not compromise on performance. They share similar inverter technology and energy-efficient characteristics as their larger counterparts, ensuring that users can enjoy a comfortable climate in a smaller footprint.

With an emphasis on user-friendly design, all these models come with intuitive remote controls, allowing for easy temperature adjustments and scheduling. Some units even offer Wi-Fi connectivity for remote access and monitoring via smartphone apps.

The CZ-18BT1U, often paired with these outdoor units, serves as an innovative air conditioning solution that supports energy efficiency and provides reliable cooling performance.

Overall, the Panasonic CU-KS and CS series units are ideal for consumers looking for modern, efficient, and environmentally friendly air conditioning solutions. Their combination of advanced technologies, user-centric design, and eco-conscious operation set them apart in the competitive HVAC market.