Panasonic CU-KS12NK1A CS-KS18NB4UW& CZ-18BT1U, CU-KS18NKUA, SHC : Sensible Heat Capacity BTU/h

Models: CS-KS18B4UW & CZ-18BT1U CS-KS12NB41 & CZ-18BT1U CU-KS12NK1A CU-KS18NKUA

1 136
Download 136 pages 28.94 Kb
Page 33
Image 33
SHC : Sensible Heat Capacity (BTU/h)

Indoor Unit

: CS-KS18NB4UW & CZ-18BT1U

 

 

 

 

 

 

 

 

Outdoor Unit

: CU-KS18NKUA

 

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

 

< Cooling Capacity (Low Ambient) >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

17,500 BTU/h

 

 

AIR FLOW RATE:

 

341 CFM

 

 

INDOOR

 

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

WB

DB

 

 

0

5

 

15

25

 

35

45

55

 

 

 

 

 

 

(-17.8)

(-15.0)

 

(-9.4)

(-3.9)

 

(1.7)

(7.2)

(12.8)

 

 

 

 

TC

 

13,400

13,430

 

13,440

13,470

 

13,500

13,520

13,510

 

 

 

72 (22.2)

SHC

 

9,740

9,740

 

9,740

11,860

 

9,740

9,800

9,800

 

 

59

76 (24.4)

SHC

 

10,930

10,930

 

10,930

13,050

 

11,000

11,000

11,000

 

 

(15.0)

80 (26.7)

SHC

 

12,190

12,190

 

12,190

13,470

 

12,190

12,260

12,190

 

 

 

84 (28.9)

SHC

 

13,380

13,380

 

13,380

13,470

 

13,380

13,450

13,450

 

 

 

88 (31.1)

SHC

 

13,400

13,430

 

13,440

13,470

 

13,500

13,520

13,510

 

 

 

 

TC

 

13,260

13,300

 

13,370

13,480

 

13,560

13,640

13,670

 

 

 

72 (22.2)

SHC

 

7,950

7,950

 

7,950

11,860

 

8,080

8,080

8,140

 

 

63

76 (24.4)

SHC

 

9,140

9,140

 

9,210

13,050

 

9,270

9,270

9,340

 

 

(17.2)

80 (26.7)

SHC

 

10,400

10,400

 

10,400

13,480

 

10,530

10,530

10,600

 

 

 

84 (28.9)

SHC

 

11,590

11,590

 

11,590

13,480

 

11,720

11,720

11,790

 

 

 

88 (31.1)

SHC

 

12,790

12,790

 

12,850

13,480

 

12,920

12,980

12,980

 

 

 

 

TC

 

12,980

13,040

 

13,170

13,380

 

13,530

13,670

13,760

 

 

 

72 (22.2)

SHC

 

6,090

6,160

 

6,220

11,860

 

6,360

6,420

6,420

 

 

67

76 (24.4)

SHC

 

7,280

7,350

 

7,420

13,050

 

7,550

7,610

7,680

 

 

(19.4)

80 (26.7)

SHC

 

8,540

8,610

 

8,680

13,380

 

8,810

8,870

8,870

 

 

 

84 (28.9)

SHC

 

9,740

9,800

 

9,870

13,380

 

10,000

10,070

10,070

 

 

 

88 (31.1)

SHC

 

11,000

11,000

 

11,060

13,380

 

11,190

11,260

11,330

 

 

 

 

TC

 

12,550

12,630

 

12,830

13,160

 

13,390

13,600

13,750

 

 

 

72 (22.2)

SHC

 

4,230

4,230

 

4,370

11,860

 

4,570

4,630

4,700

 

 

71

76 (24.4)

SHC

 

5,430

5,490

 

5,560

13,050

 

5,760

5,820

5,890

 

 

(21.7)

80 (26.7)

SHC

 

6,690

6,690

 

6,820

13,160

 

7,020

7,080

7,150

 

 

 

84 (28.9)

SHC

 

7,880

7,950

 

8,010

13,160

 

8,210

8,280

8,340

 

 

 

88 (31.1)

SHC

 

9,070

9,140

 

9,210

13,160

 

9,400

9,470

9,540

 

 

 

 

TC

 

12,010

12,110

 

12,380

12,850

 

13,150

13,440

13,650

 

 

75

76 (24.4)

SHC

 

3,640

3,700

 

3,770

12,850

 

4,030

4,170

4,230

 

 

(23.9)

80 (26.7)

SHC

 

4,900

4,960

 

5,030

12,850

 

5,290

5,360

5,490

 

 

 

84 (28.9)

SHC

 

6,090

6,160

 

6,220

12,850

 

6,490

6,620

6,690

 

 

 

88 (31.1)

SHC

 

7,280

7,350

 

7,420

12,850

 

7,680

7,810

7,880

 

 

 

TC : Total Cooling Capacity (BTU/h)

SHC : Sensible Heat Capacity (BTU/h)

 

NOTE

1.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

2.Above data represents the value when the operation frequency of a compressor is fixed.

33

Page 33
Image 33
Panasonic CU-KS12NK1A, CS-KS12NB41 & CZ-18BT1U CS-KS18NB4UW& CZ-18BT1U, CU-KS18NKUA, SHC : Sensible Heat Capacity BTU/h