1.Refrigeration (armored) tape
2.Insulated staples or clamps for connecting wire (See local codes)
3.Putty
4.Refrigeration lubricant
5.Clamps or saddles to secure refrigerant tubing
2. Installation Site Selection
2-1. Indoor Unit
WARNING
AVOID:
direct sunlight.
To prevent abnormal heat genera- tion and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surround- ing the air conditioner in a way that may block air flow.
3.3 ft. | 3.3 ft. |
(1m) | (1m) |
nearby heat sources that may affect performance of the unit.
areas where leakage of flammable gas may be expected. | 3.3 ft. |
|
places where large amounts of oil mist exist. | 3.3 ft. | 3.3 ft. | (1m) |
(1m) |
| ||
|
| (1m) |
|
DO:
select an appropriate position from which every corner of |
the room can be uniformly cooled. |
select a location that will hold the weight of the unit. |
select a location where tubing and drain hose have the |
shortest run to the outside. |
allow room for operation and maintenance as well as unre- |
stricted air flow around the unit. (Fig. 1) |
install the unit within the maximum elevation difference (H) |
above or below the outdoor unit and within a total tubing length |
(L) from the outdoor unit as detailed in Table 3 and Fig. 2. |
install the indoor unit more than 3.3' (1 m) away from any |
Outdoor unit
Fig. 1
Indoor unit
Tubing length (L) | Elevation difference (H) |
Fig. 2
antenna or power lines or connecting wires used for television, |
radio, telephone, security system, or intercom. Electrical noise |
from any of these sources may affect operation. |
Table 3
CAUTION
Air delivery will be degraded if the distance from the floor to the ceiling is greater than 10 ft. (3 m).
| Max. Allowable Tubing | Limit of Tubing | Limit of Elevation | Required Amount of |
Model | Length at Shipment | Length (L) | Difference (H) | Additional Refrigerant |
| (ft.) | (ft.) | (ft.) | (oz./ft.)* |
|
|
|
|
|
25 | 65 | 23 | 0.16 | |
|
|
|
|
|
25 | 100 | 50 | 0.27 | |
|
|
|
|
|
*If total tubing length becomes 25 to 65 ft. (Max.) or 25 to 100 ft. (Max.), charge additional refrigerant (R410A) by 0.16 or 0.27 oz./ft. No additional charge of compressor oil is necessary. For more detailed charging information, refer to the Technical & Service Manual.