Panasonic CS-KS12NB41 & CZ-18BT1U Cooling Capacity, CS-KS12NB41& CZ-18BT1U, CU-KS12NK1A

Models: CS-KS18B4UW & CZ-18BT1U CS-KS12NB41 & CZ-18BT1U CU-KS12NK1A CU-KS18NKUA

1 136
Download 136 pages 28.94 Kb
Page 30
Image 30
5-2. Cooling Capacity

5-2. Cooling Capacity

Indoor Unit

: CS-KS12NB41 & CZ-18BT1U

 

 

 

 

 

 

 

Outdoor Unit

: CU-KS12NK1A

 

 

 

 

 

 

 

 

 

Power Supply : 115V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Cooling Capacity >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

11,900 BTU/h

 

AIR FLOW RATE:

235 CFM

 

INDOOR

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. oF (oC)

 

 

AMBIENT TEMP. oF (oC)

 

 

 

WB

DB

 

65

75

85

 

95

105

115

 

 

 

 

(18.3)

(23.9)

(29.4)

 

(35.0)

(40.6)

(46.1)

 

 

 

TC

8,350

8,570

8,800

 

8,930

9,210

7,830

 

 

72 (22.2)

SHC

6,340

6,430

6,570

 

6,610

6,800

6,060

 

59

76 (24.4)

SHC

7,210

7,300

7,440

 

7,480

7,660

6,930

 

(15.0)

80 (26.7)

SHC

8,120

8,210

8,350

 

8,400

8,530

7,830

 

 

84 (28.9)

SHC

8,350

8,570

8,800

 

8,930

9,210

7,830

 

 

88 (31.1)

SHC

8,350

8,570

8,800

 

8,930

9,210

7,830

 

 

 

TC

12,230

12,030

11,790

 

11,580

10,580

7,950

 

 

72 (22.2)

SHC

7,070

6,930

6,840

 

6,700

6,200

4,970

 

63

76 (24.4)

SHC

7,940

7,800

7,710

 

7,570

7,070

5,840

 

(17.2)

80 (26.7)

SHC

8,850

8,720

8,580

 

8,490

7,980

6,750

 

 

84 (28.9)

SHC

9,720

9,590

9,450

 

9,360

8,850

7,620

 

 

88 (31.1)

SHC

10,590

10,450

10,360

 

10,230

9,720

7,950

 

 

 

TC

12,460

12,290

12,070

 

#

11,900

10,700

8,040

 

 

 

CI

0.82

0.96

1.10

 

1.20

1.25

1.07

 

 

72 (22.2)

SHC

5,790

5,700

5,610

 

5,520

4,970

3,870

 

67

76 (24.4)

SHC

6,660

6,570

6,480

 

6,380

5,880

4,740

 

(19.4)

80 (26.7)

SHC

7,570

7,480

7,390

 

7,300

6,750

5,650

 

 

84 (28.9)

SHC

8,440

8,350

8,260

 

8,170

7,620

6,520

 

 

88 (31.1)

SHC

9,310

9,220

9,130

 

9,040

8,490

7,390

 

 

 

TC

12,640

12,490

12,300

 

12,170

10,770

8,100

 

 

 

CI

0.84

0.98

1.13

 

1.22

1.25

1.07

 

 

72 (22.2)

SHC

4,460

4,420

4,330

 

4,280

3,690

2,680

 

71

76 (24.4)

SHC

5,330

5,290

5,200

 

5,150

4,560

3,550

 

(21.7)

80 (26.7)

SHC

6,250

6,200

6,110

 

6,060

5,470

4,460

 

 

84 (28.9)

SHC

7,120

7,070

6,980

 

6,930

6,340

5,330

 

 

88 (31.1)

SHC

7,980

7,940

7,850

 

7,800

7,210

6,200

 

 

 

TC

12,730

12,610

12,450

 

12,370

10,780

8,120

 

 

 

CI

0.86

1.01

1.15

 

1.25

1.25

1.07

 

75

76 (24.4)

SHC

4,050

4,010

3,960

 

3,920

3,370

2,450

 

(23.9)

80 (26.7)

SHC

4,970

4,920

4,880

 

4,830

4,280

3,370

 

 

84 (28.9)

SHC

5,840

5,790

5,740

 

5,700

5,150

4,240

 

 

88 (31.1)

SHC

6,700

6,660

6,610

 

6,570

6,020

5,100

TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB

:Outdoor Ambient Temp. 95 °F (35 °C) DB

2.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.