KX-P7100

4.4.11. High Voltage Control Circuit

1.Charge Control Circuit

This circuit consists of a DC-DC converter, which boosts +24V to approximately +5.4kV ( constant current approx. +300µA ) for the charge corona. nCHGCTL signal controls the charge output. If the signal goes low,the output is turned on.

2.Grid Circuit

When the charge circuit is activated ( when the signal nCHGCTL is low ), this circuit is activated and approximately +900V is generated on the grid.

3.Development Bias Control Circuit

When the charge circuit is activated ( when the signal nCHGCTL is low ), this circuit is activated.

This voltage is changed between +100V and +500V in accordance with the PWM ( Pulse Width Modulation ) signal nDB when the signal nDBCH is low. Also approximately - 150V is generated when signal nDB and nDBCH is high.

4.Transfer Control Circuit

This circuit consists of a DC-DC converter, which boosts +24V to -400V-3000V ( constant current ).

This current is changed between -4µA and -20µA in accordance with the PWM ( Pulse Width Modulation ) signal nTR when the signal nTRCTL is high.

5.Transfer Roller Cleaning Control Circuit

This circuit consists of a DC-DC converter, which boosts +24V to +1500V. This voltage is generated when signal nTR is high and nTRCTL is low.

62

Page 62
Image 62