4.4.14.3. The Switchback Solenoid Drive Control Circuit

The switchback solenoid is used for controlling media switchback when the printer is auto duplex printing. The CPU IC11 outputs high level EXITCTL signal from pin43 to the transistor Q22. The transistor Q22 and Q25 are turned on and supplies +24Vpower to the solenoid.