ENGLISH
43
Basic Operation
Registration of input signal data
The input signal data must be registered because
it is not registered on shipment of the projector.
MENU
Press to display the MAIN
MENU screen.
Press to select “SIGNAL
LIST”.
Press to display the
“REGISTERED SIGNAL
LIST” menu.
The memories extend
over 12 pages (A to L with
8 data items each, giving
a total of 96 memories).
ENTER
MAIN MENU
PICTURE
POSITION
ADVANCED MENU
DISPLAY LANGUAGE
DISPLAY OPTION
PROJECTOR SETUP
P IN P
TEST PATTERN
SIGNAL LIST
SECURITY
NETWORK
MENU SELECT
SUB MENU

Registration of new data

When a new signal is supplied, press MENU on the
remote control or operating section of the main unit.
When its data has been registered, the “MAIN MENU”
screen is displayed.
Note
The data of 96 input signals can be registered.
The signals supporting the installed input module
are input and their data registered.
The memories are numbered over 12 pages (A to L:
8 data items can be registered on each page), and
the data is registered in the unused memory with
the lowest number. If all the memories are used, the
data of the old signals is overwritten in sequence.
The names of the registered data are automatically
determined by the input signals and memory
numbers.
If a menu is being displayed, the new signals will be
registered at the instant they are input.

Renaming the registered signals

Press ▲▼◄ to select the 1.

signal whose details are to be

displayed.

REGISTERED SIGNAL LIST
A1:SVGA72-A1 RGB1 −−−
A2:SVGA72-A2 RGB1 −−−
A3:SVGA72-A3 RGB1 −−−

Press ENTER.2.

The “REGISTERED SIGNAL STATUS” screen
will be displayed.
REGISTERED SIGNAL STATUS
NAME
MEMORY NO
INPUT
fH
fV
SYNC.STATE
SVGA72-A2
A2
RGB1
48.08kHz
72.17Hz
H(POS)
V(POS)
The data items including the input signal name,
memory number, input terminal, frequency and
sync signal are automatically identified and
displayed.
When MENU is pressed, the “REGISTERED
SIGNAL LIST” screen is restored.

Press ENTER.3.

The “RENAME” screen will be displayed.
▲▼◄►
ENTER
DEFAULT
MENU