ENGLISH
69
Special Features
Press ENTER.5.
The “3COLORS:RED”, “3COLORS:GREEN” or
“3COLORS:BLUE” screen will be displayed.
If you selected “7COLORS”, the
“7COLORS:RED”, “7COLORS:GREEN”,
“7COLORS:BLUE”, “7COLORS:CYAN”,
“7COLORS:MAGENTA”, “7COLORS:YELLOW”,
or “7COLORS:WHITE” screen will be
displayed.
3COLORS:RED
RED
GREEN
BLUE
2048
0
0
Press ◄► to adjust the values.6.
These values can be adjusted from 0 to 2 048.
Note
The effects of correcting the adjustment colour:
When tuning the correction colour that is the same
as the adjustment colour: the brightness of the
adjustment colour changes.
When tuning the correction colour RED: RED is
added to or reduced from the adjustment colour.
When tuning the correction colour GREEN: GREEN
is added to or reduced from the adjustment colour.
When tuning the correction colour BLUE: BLUE is
added to or reduced from the adjustment colour.
This adjustment should be carried out by a person
who is familiar with the projector or by a service
person because a high level of skill is required to
make successful adjustment.
Pressing DEFAULT will restore the factory defaults
for all items.
When any setting other than “OFF” has been
selected for colour matching, the “COLOR
TEMPERATURE” setting is fixed at “USER1”.
Adjusting the colour matching using a colorimeter
The “RED”, “GREEN”, “BLUE”, “CYAN”, “MAGENTA”,
“YELLOW” and “WHITE” colours can be changed to
the desired hues using a colorimeter which is capable
of measuring the chromaticity coordinates and
luminance.
Inputting the current luminance
and chromaticity coordinates
Press ▲▼ to select “COLOR 1.
MATCHING”.
DISPLAY OPTION
COLOR MATCHING
LARGE SCREEN CORRECTION
OFF
OFF
Press ◄► to select 2.
“MEASURED” or “709MODE”.
Press ENTER.3.
The “MEASURED MODE” screen will be
displayed.
MEASURED MODE
MEASURED DATA
TARGET DATA
AUTO TESTPATTERN ON
Press ▲▼ to select “MEASURED 4.
DATA”.
Press ENTER.5.
The “MEASURED DATA” screen will be
displayed.
MEASURED DATA
BLACK Y(RELATIVE)
x
y
RED Y(RELATIVE)
x
y
GREEN Y(RELATIVE)
x
y
BLUE Y(RELATIVE)
x
y
1
0.35
0.36
1400
0.67
0.33
5099
0.35
0.63
500
0.15
0.05
1/2
Use the colorimeter to 6.
measure the luminance (Y) and
chromaticity coordinates (x, y).
Press ▲▼ to select the colours, 7.
and press ◄► to select their
values.
After all the data has been input, 8.
press MENU.
The “MEASURED MODE” screen will be
displayed.
MEASURED MODE
MEASURED DATA
TARGET DATA
AUTO TESTPATTERN ON
Inputting the coordinates
of a desired colour (only
“MEASURED”)
Press ▲▼ to select “TARGET 9.
DATA”.