SNMP System Name
Enter from the keyboard.
SNMP System Location
Enter from the keyboard.
Click the [SET] button if all are adequately set.
The
■Switcher Setup SWITCHER SETUP
This window specifies sequence setups only for
8Common Setup (COMMON SETUP)
Start Display (START DISPLAY)
The image in the selected form will be displayed on the monitor when the unit is turned on.
Single Image: CH 1 – CH 8
Quad Image:
(including
Multi Image:
Sequence: SPOT SEQUENCE, MULTI SEQUENCE
When the [MULTI SCREEN SELECT] button on the front panel is pressed, the monitor display will change as fol- lows depending on the selection.
QUAD ONLY:
ALL:
8Multi-screen Sequence Setup
(MULTI SEQUENCE SETUP)
| Sequence Timing (SEQUENCE TIMING) |
| INT: The preset time to the internal timer allows the |
| sequence to step forward. |
| EXT: SEQ IN signal to the rear panel allows the |
66 | sequence to step forward. |
|
Auto Skip (AUTO SKIP)
ON: The sequence skips the step where no video is input.
OFF: The sequence does not skip the step.
Click the button to open the Multi Sequence Setup window.
8Spot-screen Sequence Setup
(SPOT SEQUENCE SETUP)
Sequence Timing (SEQUENCE TIMING)
INT: The preset time to the internal timer allows the sequence to step forward.
EXT: SEQ IN signal to the rear panel allows the sequence to step forward.
Auto Skip (AUTO SKIP)
ON: The sequence skips the step where no video is input.
OFF: The sequence does not skip the step.
Click the button to open the Spot Sequence Setup window.
8Camera View Setup (CAMERA VIEW SETUP)
Click the button to open the Camera View Setup window.
■Multi Sequence Setup MULTI SEQUENCE SETUP
8Camera Channel (CAMERA CH)
1 - 8: The selected camera image will be displayed in single spot mode.
QUAD A: Camera image 1 through 4 will be displayed in
QUAD B: Camera image 5 through 8 will be displayed in
8Time (TIME)
Available duration:
Click the [SET] button if all are adequately set.