■Connection with the Camera Site

Connection with the Camera Site

System Camera Connection

Connect the system cameras directly to the recorder.

IN

8

7

6

OUT

8

7

6

Data-multiplex Camera Connection

Connect the combination cameras and the receiver via the multiplex unit with the recorder.

Combination Cameras

Pan/Tilt Table

Receiver

POWER

ALARM

Data Multiplex

ALARM

SUSPEND

Unit

OFF

 

ON

 

 

Data Multiplex Unit WJ-MP204

4

3

2

1

 

 

 

 

SPOT

 

 

 

 

OUT

A

4

3

2

1

 

O

 

 

MULTI

RS-23

 

 

SCREEN OUT

 

 

 

 

Connection with the Monitors

Connect the spot and multi-screen monitors.

Disk Recorder

WJ-HD200

SPOT

OUT

MULTI

SCREEN OUT

Spot Monitor

Multiscreen Monitor

ALARM/REMOTE Connection

A 25-pin connector is used to accept and supply control signals.

 

 

13

 

 

 

1

 

 

25

ALARM/REMOTE

14

 

 

 

 

Pin

Designation

Pin

 

Designation

#

#

 

 

 

 

 

 

1

Alarm Reset In

 

14

Time Adjust Out

2

Alarm 1 In

 

15

Alarm 5 In

3

Alarm 2

In

 

16

Alarm 6 In

4

Alarm Recovery 1* Out

17

Alarm 7 In

5

Alarm Recovery 2 Out

18

Alarm 8 In

6

Alarm 1

Out

 

19

Signal GND

7

Alarm 2* Out

 

20

Signal GND

8

Disk End Out

 

21

Play Status Out

9

Warning Out

 

22

EXT REC MODE In

10

Alarm 3

In

 

23

No Connection

11

Alarm 4

In

 

24

Sequence In

12

REC Status Out

 

25

Sequence Out

13

Time Adjust In

 

 

 

 

16