Panasonic WJ-HD200 manual Setup Control, Miscellaneous Control, Data Log Control, Media Control

Models: WJ-HD200

1 92
Download 92 pages 3.05 Kb
Page 83
Image 83
Setup Control

Setup Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Cursor Moves

DCR:n1n2

DCR

n1=A Right

 

 

 

n1=C Upward

 

 

 

n1=E Left

 

 

 

n1=G Downward

 

 

 

n2=1 Move a step

 

 

 

n2=2 Move multi steps

 

 

 

n1n2=PD Move to lower layer

 

 

 

n1n2=P+ Move to upper layer

 

 

 

n1n2=P- Turn a newer page

 

 

 

n1n2=PU Turn an older page

 

 

 

 

Key Lock

MKL:n

MKL

n=0 Lock OFF

 

 

 

n=1 Lock ON

Recording Event

MRM:n

MRM

n=0 Normal recording

Setup

 

 

n=1 Internal timer recording

 

 

 

n=2 External timer recording

Summer Time Setup

MST:n

MST

n=0 Standard time

 

 

 

n=1 Summer time

 

 

 

 

Setup

MSU:n

MSU:n

n=0 End setup

 

 

 

n=1 Begin setup

Date&Time Setup

TSU:yyyymmddhhnn

TSU

yyyy=Year

 

 

 

mm=Month

 

 

 

dd=Day

 

 

 

hh=Hour (24-hour system)

 

 

 

nn=Minute

 

 

 

 

Miscellaneous Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

OSD Show/Hide

DIN:n

DIN

n=+ Toggle

 

 

 

n=0 Hidden

 

 

 

n=1 Shown

Communication Check

RCK

RCK

 

Time&Date Search

ZTS:yyyymmddhhnnss

ZTS

yyyy=Year

 

 

 

mm=Month

 

 

 

dd=Day

 

 

 

hh=Hour (24-hour system)

 

 

 

nn=Minute

 

 

 

ss=Second

Data Log Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Log Total Size Inquiry

ILB:k

ILB:k:bbbbb

k=0 Alarm log

 

 

 

bbb=001 to 099 (in decimal)

 

 

 

 

Log Erase

ILC:n

ILC:n

n=0 Alarm log

 

 

 

n=1 System log

Log Recorded

ILQ:k

ILQ:k:bbbbb:ddddd:(:E)

k=0 Alarm log

Size Inquiry

 

 

bbbbb=00001 - 00999 (Oldest log)

 

 

 

ddddd=00001 - 00999 (Size of log)

 

 

 

E=Overwrite

Log Readout

ILR:k:sss:mmm

ILR:k:<log data s1>s1

 

 

<log data s2>s2

 

 

<log data sn>F

k=0 Alarm log

sss=001-2 000 Start Address mmm=001-100 Decimal # of log <log data sn>=yymmddhhnnss sn=0-9 and F Cyclic number (F is put at data end)

Media Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Disk End Notice Setup

MDE:n

MDE

n=0 End is not notified

 

 

 

n=1 End is notified

Disk End Notice

 

HDE

 

84

Page 83
Image 83
Panasonic WJ-HD200 manual Setup Control, Miscellaneous Control, Data Log Control, Media Control