Paradyne 8510 DSL, 8310 MVL manual

Models: 8510 DSL 8310 MVL

1 98
Download 98 pages 33.07 Kb
Page 91
Image 91
Manual background

Traps

Event

Trap Class

Comment

Trap # ± MIB *

 

 

 

 

xDSL test start

normal

Test started by any

6±dsl

 

 

means.

 

 

 

 

 

xDSL test clear

normal

Test over.

106±dsl

 

 

 

 

DHCP filter security failure

minor

Can not add new

11±dhcp

 

 

route to route table

 

 

 

because maximum

 

 

 

number of stored

 

 

 

rules reached.

 

 

 

 

 

SN device mismatch

minor

SN identified on port

07±dsl

 

 

N does not match

 

 

 

device described in

 

 

 

port configuration

 

 

 

role.

 

 

 

 

 

SN device mismatch clear

minor

SN identified on port

107±dsl

 

 

N now matches

 

 

 

device described in

 

 

 

port configuration

 

 

 

table.

 

 

 

 

 

SN loss of power

minor

Card received ªlast gaspº message from SN, followed by a link down condition one minute later.

17±dsl

SN device failure

major

Operating software

18±dsl

 

 

has detected an

 

 

 

internal device

 

 

 

failure. The SN is still

 

 

 

operating.

 

 

 

 

 

SN selftest failure

minor

Failure of the SN's

19±dsl

 

 

hardware

 

 

 

components. This

 

 

 

trap is only sent if

 

 

 

the hardware failure

 

 

 

still allows sending

 

 

 

traps.

 

 

 

 

 

SN fatal reset

Ð-

Variable binding field

20±dsl

 

 

contains device

 

 

 

failure code.

 

 

 

 

 

Dynamic filter injection

warning

Cannot inject or

10±dhcp

failure

 

delete dynamic filters

 

 

 

to SN on port N.

 

 

 

 

 

* MII = MIB ll, ent = Entity MIB, dsl = hotDSL Enterprise MIB, sys = hotSys Enterprise MIB, dhcp = DHCP Enterprise MIB, diag = hot_diag.mib

8000-A2-GB26-00

May 1998

B-3

Page 91
Image 91
Paradyne 8510 DSL, 8310 MVL manual