Models 2603, 2621, and 2635 Getting Started Guide

10 • System Configuration

 

 

Error Log

The Error Log webpage shows recent configuration errors and provides for the configuration of the Syslog. (See figure 78.) Two parameters are configurable for the Syslog.

Syslog Host: enter the IP address of the Syslog (Default = 0.0.0.0)

Syslog Facility: select the type of syslog facility (Default = disabled)s

Click on the Update button to activate the selected parameters. Default value is a disabled Syslog.

Figure 78. Error Log and Syslog Settings

SNMP Daemon

For remote management from an SNMP capable management station, the IPLink’s SNMP Daemon must be configured. To identify a specific IPLink, configure the Static Variables which the system administrator may use for link identification.

The Community Table has three configurable parameters.

Password: this is the password which the remote management station must use to access the IPLink for reading/writing the SNMP variables.

Management IP: the IP address of the management station.

Access: select either Write or Read. The management station can be authorized to configure the IPLink by ‘writing’ to the SNMP variables or limited to a ‘read’-only function.

To delete an entry, click on the ‘Del’ box and click on the Update button.

Error Log

102

Page 102
Image 102
Patton electronic 2603, 2621, 2635 manual Error Log, Snmp Daemon