Models 2603, 2621, and 2635 Getting Started Guide

6 • WAN Services

 

 

2.On the Menu, go to Services Configuration, then to WAN. Delete the factory default WAN services already defined.

3.Click on Create a new service in the main window, select “Frame Relay routed” and click on Continue.

4.Enter the description for the circuit in the Description field. This is a mandatory field. Without a descrip- tion you cannot create a WAN service. (See figure 38.)

Figure 38. Frame Relay routed configuration

Description: FR routed

DLCI. Enter DLCI number. Consult with your service provider for the DLCI number required.

Encapsulation Method. Defines the RFC1490 encapsulation type that will be used by the channel. Choose the encapsulation method best suited for your network needs from the following options:

Routed IP (default value)

Raw

WAN IP address. Enter the IP address assigned to the WAN port (V.35, X.21, or T1/E1)

Enable NAT on this interface. In this example leave this option blank

5.Click the Create button.

6.Go to System Configuration > WAN > Edit (for Frame Relay Routed service) > Edit ‘IP Interface’

7.Enter the WAN IP Address, in this example = 192.168.164.2, and click on the Create button.

8.From the ‘IP Interface’ web page, click on Edit ‘Frame Relay’, then click on Edit ‘Frame Relay Channel’ (See figure 39.)

WAN Service Configuration

64

Page 64
Image 64
Patton electronic 2621, 2603, 2635 manual Description FR routed