Pelco DX3016-060 manual AC power socket, RS-232C connector, Alarm in terminals, GND terminals

Models: DX3016-120 DX3009-060 DX3016-060

1 85
Download 85 pages 40.17 Kb
Page 12
Image 12

6.AC power socket

This socket is for a 100-240 VAC power cord.

7.RS-232C connector

This is where a PelcoNet™ Transmission System can be connected for remote view- ing and control of cameras.

8.ALARM IN terminals

These are input terminals for alarm signals.

GND terminals

These are earth ground terminals for the ALARM IN terminals. Use only the terminal screws provided with this unit; otherwise, the recorder could be damaged or connec- tions may be poor.

9.I/O terminals

GND terminals

These are ground terminals for the input/output terminals.

CLOCK ADJ terminal

This is an input terminal to set the time display. The time display is adjusted to the nearest hour (00 minutes, 00 seconds) when this terminal receives the clock adjust signal.

REC terminal

This is an input terminal to start recording.

POWER ON terminal

This is an input terminal to turn on the recorder through a peripheral device.

POWER OFF terminal

This is an input terminal to turn off the recorder through a peripheral device.

ALARM OUT terminal

This is an output terminal to indicate that an alarm recording is being made.

MODE OUT terminal

This is an output terminal to indicate the recorder’s current mode. Select the mode in the Rear Terminal menu.

CALL OUT terminal / CALL OUT GND terminal

This is an isolated (optically coupled) output to indicate information such as the hard disk drive is full. Refer to the Warnings section.

DC 5V OUT terminal

This terminal is for direct current voltage output. The maximum current is 30 mA.

10.SCSI connector

This connector is for peripheral recording devices.

11.RESET button

When pressed, the present time is erased, the system is reset, and the power is turned off.

SCSI TERMINATION switch

When set to ON, the termination function is enabled; when set to OFF, the termination function is disabled. Set the switch ON when nothing is connected to the SCSI connector.

12.Ethernet connector (DX3016 Models Only)

Not used.

Pelco Manual C681M-D (2/02)