<DEVICE CHECK> |
|
SCSI ID0:HDD (30GB) |
|
ID1:HDD ( 9GB) |
|
ID2:NONE |
|
ID3:NONE |
|
ID4:NONE |
|
ID5:NONE |
|
INITIALIZE | |
BOOT UP DELAY | 00 |
ID4:RDD |
|
ID5:DDS |
|
| |
BOOT UP DELAY | 00 |
6.Connect the power cord to the recorder, and then plug the power cord into a wall socket.
7.Turn on power to peripheral recording devices first, and then turn on the power to the recorder. Power to the cameras and monitor can be turned on before or after turning on the recorder.
If there are no peripheral devices connected to the SCSI terminal, the installation is complete. Proceed to the Programming section.
If there are peripheral devices connected to the SCSI terminal, the recorder automati- cally detects peripheral recording devices connected to the SCSI terminal.
If a hard drive(s) has been added, refer to the Adding a Hard Drive(s) section for more information about turning on the recorder.
If a peripheral device takes a long time to start up, refer to the section on
ADDING OR REMOVING A COPY OR ARCHIVE DEVICE
1.Turn off the power.
2.Connect or disconnect the copy or archive device.
3.Turn on the power.
ADDING A HARD DRIVE(S)
This section applies only to devices connected to ID1-ID3.
WARNING: All data will be lost on the current drive(s) after you install an additional hard drive(s) and turn the power back on. Back up data you want to save before turning off the power to add a hard drive(s).
NOTE: The DX3000 uses the native format of the added drive(s); therefore, any added drive(s) do not have to be reformatted.
Up to two
1.If a hard drive(s) has been added, a screen similar to the first one on the left appears after turning on the power. This screen shows a peripheral device connected to ID1.
If the second screen to the left appears, it is possible that there is either a poor con- nection, overlapping SCSI ID numbers, or an error in SCSI ID number settings. In this case, turn the SHUTTLE ring twice in the clockwise direction. Main power to the re- corder is turned off. Check the connection and SCSI ID settings.
2.Make sure that the connected device(s) is recognized correctly.
If the connected device(s) is not displayed correctly, make sure that the cursor is be- side POWER OFF. If the cursor is not beside POWER OFF, turn the JOG dial to move the cursor beside POWER OFF, and then turn the SHUTTLE ring twice to the right. The recorder’s power is turned off. Make sure that the connection of the external device and the setting of the SCSI ID number is correct, and then turn the power back on.
3.Turn the JOG dial to select INITIALIZE.
4.Turn the SHUTTLE ring to the right when “Turn the SHUTTLE RING >> to EX- ECUTE.” is displayed.
16 | Pelco Manual |