137
Linking AF Point and AE During Multi-Segmented Metering
In [Link AF Point and AE] (p.106) of the [ACustom Setting] menu, you can link the exposure and AF point in the focusing area during
1 | Off | Exposure is set separately from AF point. |
2 | On | Exposure is set in accordance with AF point. |
Using the |
| |
Metering is weighted at the center of the |
| |
screen. Use this metering when you want |
| |
to compensate the exposure by | 5 | |
experience, instead of leaving it to the | ||
camera. The illustration shows that | Function | |
sensitivity increases as the pattern height | ||
| ||
increases (center). This mode does not |
| |
automatically compensate for backlit scenes. | Reference | |
Using the Spot Metering | ||
| ||
With spot metering, brightness is |
| |
measured only within a limited area at the |
| |
center of the screen as shown in the |
| |
illustration. You can use this in |
| |
combination with the AE lock (p.148) |
| |
when the subject is extremely small and |
| |
proper exposure is difficult to obtain. |
|
Setting the Meter Operating Time
Sets the exposure metering time in [Meter Operating Time] in the [ACustom Setting] menu (p.106). The default setting is [10 sec].
1 | 10 sec | Sets exposure metering timer to 10 seconds. |
2 | 3 sec | Sets exposure metering timer to 3 seconds. |
3 | 30 sec | Sets exposure metering timer to 30 seconds. |