Repair Manual

Macro 5 SLR Camera

 

 

Operation

The following procedures sequentially detail the picture taking operation. For a simplified explanation of this picture taking operation refer to the flow diagrams in Figures 2-1 and 2-2.

Camera Setup

1.Set the camera to the desired magnification.

Note: If the magnification selector is improperly set (between settings), the camera will not function. For detailed information on how to select magnification, refer to the Macro 5 SLR User's Guide.

Magnification:

Lens-to-subject

Lens focal

Effective lens

Depth

 

distance

2

aperture

3

 

length

of field

0.2x (20%)

52in./130cm

221mm

f/20

10.6in./27cm

0.4x (40%)

26in./66cm

188mm

f/34

3.8in./10cm

1x (100%)

9.9in./25cm

128mm

f/47

0.86in./2.2cm

2x (200%)

4.8in./13cm

85.4mm

f/67

0.31in./0.8cm

3x (300%)

3.1in./8cm

64mm

f/100

0.20in./0.5cm

2.If applicable, plug in desired filter kit (Polarizer or Fluorescein).

Note: Use of specified filter kit is optional. For detailed information, refer to the provided Macro 5 SLR User's Guide.

Filter Kit:

Polarizer:

Reduces reflections from flash units when taking pictures of

 

glossy or glass subjects.

Fluorescein: For external ophthalmic photography includes #2A yellow barrier filter and #47A blue exciter filters.

21

Page 21
Image 21
Polaroid 111523 manual Operation, Camera Setup, Filter Kit