Electrostatic Discharge Warning

The camera circuitry can easily be damaged by static discharges. Always use an anti-static mat and a wrist-strap when servicing the camera's PC Boards.

Inspection and Cleaning

Whenever disassembling the camera for parts replacement, always inspect the following assemblies for dust and debris (reagent developer).

Note: If necessary, clean the replaced parts with a water dampened tissue or soft clean rag to assure that dust and debris (reagent developer)

do not interfere with camera performance.

Front Cover Assembly

Camera Back Rollers

Turret Assembly

Cone Assembly

Shutter Assembly

Viewfinder Assembly

Disassembly/Assembly of Camera

This section of the Service Manual describes disassembly/reassembly procedures. Before performing any of these procedures, always make sure that the camera is turned off and the film pack is removed.

CAUTION

To prevent any chance of electric shock, the camera should be opened only by a qualified service person, and only after it has been disconnected from its power source (film pack battery); make sure the strobe capacitors are fully discharged (dumped). Also, take care not to damage (bend or distort) any of the camera components during disassembly and reassembly.