Repair Manual | Macro 5 SLR Camera |
|
|
From Figure 2-1
If S1 button released, range lights go out in 15 seconds. Press S1 button lightly to turn on again.
Picture Taking
Lightly press shutter
button S1/S2
S1 closes
Range lights ON
Power latches ON
Strobes charge
Press shutter button S1/S2
Green status lights On
(Ready)
Status OK
Self-check routine
starts
|
|
|
| |
Checks status of: |
| |||
- Control panel settings |
| |||
- Magnification settings |
| |||
- Lighten/Darken setting |
| |||
- Film door | 30 second | |||
- RS232 receptacle | ||||
continuous | ||||
- Battery | ||||
loop | ||||
- Picture count | ||||
| ||||
- |
| |||
- Auxiliary receptacle |
| |||
- Internal timer |
| |||
- Strobes |
| |||
|
|
|
|
Strobes not | Strobes | |
charged | charged | |
Warning | S2 closes | |
beep | ||
| ||
| - Strobes fire | |
| - Shutter actuates |
Camera powers down (shuts off) when:
-Picture counter reaches zero (0)
-
Picture taken
Figure 2-2 Picture Taking