Configuration Files

This configuration attribute is defined as follows:

 

Permitted

 

 

 

Attribute

Values

Default

Interpretation

 

 

 

 

ind.idleDisplay.mode

1 (default), 2,

Null

The idle display animation screen layouts.

 

3

 

For example, for the SoundPoint IP 330/320:

 

 

 

 

 

 

If set to 1 or Null, the idle display animation

 

 

 

 

size is 87 x 11 pixels.

 

 

 

If set to 2, the idle display animation size is 87

 

 

 

 

x 22 pixels.

 

 

 

If set to 3, the idle display animation size is

 

 

 

 

102 x 22 pixels.

 

 

 

 

ind.idleDisplay.enabled

0, 1

0

If set to 1, the idle display may support

 

 

 

presentation of a custom animation if configured

 

 

 

in the animation section of sip.cfg.

 

 

 

 

 

Animations <anim/> <IP_300/>, <IP_330/>, <IP_400/>, <IP_500/>, <IP_600/>, <IP_4000/>, and <IP_7000/>

This section defines bitmap animations composed of bitmap/duration couples. In the following table, x=IP_300, IP_330, IP_400, IP_500, IP_600, IP_4000 or IP_7000, y is the animation number, z is the step in the animation. Note that IP_300 parameters affect SoundPoint IP 301 phones, IP_330 parameters affect SoundPoint IP 320 and 330 phones, IP_400 parameters affect SoundPoint IP 430 phones, IP_500 parameters affect SoundPoint IP 501 phones and IP_600 parameters affect SoundPoint IP 550, 560, 600, 601, 650, and 670 phones, IP_4000 parameters affect SoundStation IP 4000 and 6000 phones, and IP_7000 parameters affect SoundStation IP 7000 phones.

Note

As of SIP 2.2.0, a maximum of 24 frames per animation is supported.

 

 

 

 

 

 

 

 

Attribute

 

Permitted Values

Interpretation

 

 

 

 

ind.anim.x.y.frame.z.bitmap

 

A bitmap name defined

Bitmap to use.

 

 

previously.

Note that it must be defined already, refer to

 

 

 

Platform <IP_300/>, <IP 330/>, <IP_400/>,

 

 

 

<IP_500/>, <IP_600/>, <IP_4000/>, and

 

 

 

<IP_7000/> on page A-80.

 

 

 

 

ind.anim.x.y.frame.z.duration

 

positive integer

Duration in milliseconds for this step. 0=infinite.

 

 

 

 

A - 81

Page 235
Image 235
Polycom 1725-11530-310 manual Platform IP300/, IP 330/, IP400, IP500/, IP600/, IP4000, IP7000/ on page A-80