Manual background

49

No. of

Deflection

 

 

 

Header Span (ft.)

 

 

 

Trimmer Studs

 

9’

10’

11’

12’

13’

 

14’

15’

16’

 

L/480

700

630

573

458

360

 

288

234

193

1

 

 

 

 

 

 

 

 

 

 

L/360

700

630

573

525

480

 

384

313

257

 

 

 

 

 

 

 

 

 

 

 

 

L/240

700

630

573

525

485

 

450

420

386

 

 

 

 

 

 

 

 

 

 

 

 

L/480

1085

791

594

458

360

 

288

234

193

2

 

 

 

 

 

 

 

 

 

 

L/360

1400

1055

792

610

480

 

384

313

257

 

 

 

 

 

 

 

 

 

 

 

 

L/240

1400

1245

792

864

720

 

577

469

386

 

 

 

 

 

 

 

 

 

 

 

Values listed for each deflection represent the least value of the bearing capacity of the trimmer, shear or bending capacity of the header or the actual deflection at the design load.

Refer to Technical Bulletin #30 for supporting headers in PBS Wall SIPs (www.pbssips.com). Note: Trimmer stud design capacities must be reviewed.