Maximum Floor Span Maximum Roof Span

44

Panel Core

Deflection

 

 

 

 

Panel Span (ft.)

 

 

 

 

Thickness

 

 

 

 

 

 

 

 

 

 

 

4’

8’

10’

12’

14’

16’

18’

20’

22’

24’

 

 

 

 

 

 

 

 

 

 

 

 

 

L/360

132

136

93

60

48

40

29

21

 

 

7 1/4”

 

 

 

 

 

 

 

 

 

 

 

L/240

318*

148*

107*

91

70

54

42

31

NA

NA

 

 

 

 

 

 

 

 

 

 

 

 

 

L/180

318*

148*

107*

92*

85

54

48

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 1/4”

L/360

197

164*

124*

72

66

61

48

34

29

24

 

 

 

 

 

 

 

 

 

 

 

L/240

318*

164*

124*

107*

96*

84*

70

49

43

36

 

 

 

 

 

 

 

 

 

 

 

 

 

L/180

318*

164*

124*

107*

96*

84*

76*

65

56

47

 

 

 

 

 

 

 

 

 

 

 

 

 

L/360

258

143*

103*

86

83

77*

61

42

37

31

11 1/4”

 

 

 

 

 

 

 

 

 

 

 

L/240

318*

143*

103*

93*

85*

77*

68*

59*

54*

47

 

 

 

 

 

 

 

 

 

 

 

 

 

L/180

318*

143*

103*

93*

85*

77*

68*

59*

54*

49*

 

 

 

 

 

 

 

 

 

 

 

 

* indicates ultimate load divided by 3 for the design capacity. 4’ span is a minimum two span condition.

Panels require a minimum of 1-1/2” bearing. I-Joist splines are spaced 4’ o.c.

Floor panels should have a 3/4” minimum top skin or a 7/16” top skin overlayed with 7/16” finish flooring perpendicular to the panels.

More information on this chart can be found in Technical Bulletin #13 (www.pbssips.com). Refer to Technical Bulletin #21 for floor applications (www.pbssips.com).