Manual background

52

Minimum

 

 

Attachments

 

 

 

Panel Supports

Panel Joints - Top Only

Panel Joints -

Shear

OSB Face

Top & Bottom

(plf)

Thickness

 

 

 

 

 

 

 

 

 

 

 

 

Fasteners

Spacing

Fasteners

Spacing

Fasteners

Spacing

 

7/16”

PBS

12 inches

8d nail

3 inches

8d nail

6 inches

425

Screw2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/16”

PBS

3 inches

8d nail

2 inches

8d nail

4 inches

510

Screw2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/16”

PBS

4 inches

8d nail - 2

3 inches

8d nail - 2

6 inches

917

Screw2

rows

rows

 

 

 

 

 

 

 

 

 

 

 

 

 

23/32”

PBS

4 inches

8d nail - 2

3 inches

8d nail - 2

6 inches

1136

Screw2

rows

rows

 

 

 

 

 

 

 

 

 

 

 

 

 

1.The maximum panel height-to-width ratio shall be 4.5:1.

2.Premier Building Systems specially-designed big screws.

Load Chart 11:

Premier SIPs1 Maximum

Allowable Diaphragm Loads

Page 52
Image 52