Premier Floors manual Spline Connection

Models: Floors

1 56
Download 56 pages 20.64 Kb
Page 8
Image 8
Spline Connection

Spline Connection

Depending on the load requirements and application, Premier Panels are joined together in one of three fashions: Premier spline (Type ‘S’ panel), lumber spline (double 2x or 3x, Type ‘L’ panel) or engineered I-joists (Type ‘l’ panel).

Premier splines – This is the most common connection between Premier Panels. Splines should be cut flush or slightly short (about 1/16”) of the foam in the panel ends. Parallel 3/16” beads of Premier Mastic are placed approximately 1/4” from each of the spline edges and along the foam-to-foam edges. Premier Mastic is used on all wood-to-wood, wood-to-foam, and foam-to-foam interfaces. Once panels are in place, the splines are nailed with 8d nails 6” o.c. or according to your shop drawing nail pattern.

8

Page 8
Image 8