Chapter 2 RFID PPI/ZGL Commands

bSets the read/write position of the transponder in the vertical (Y axis) in dot rows from the top of the label. Set to 0 if the transponder is already in the effective area without moving the media. The default value is label length minus 1 mm. The acceptable value range is 0 to label length.

cSets the length of the void printout in dot rows. The acceptable value range is 0 to label length. (This option is currently not supported.)

dSets the number of retries that will be attempted in case of read/write failure. The number will reflect in the Label Retry menu.

eError handling. Enter N for no action. Enter P to place the printer in Pause mode. Enter E to place the printer in Error mode. (This option is currently not supported.)

fSignals on applicator. Enter S to single signal. Enter D for double signal. (This option is currently not supported.)

gCertify tag with a pre-read. (This option is currently not supported.)

hSets the print speed at which “VOID” will be printed across the label. (This option is currently not supported.)

Set RFID Tag Password

Purpose This command defines the password for the tag during writing.

Format ^RZa

^RZ

Set RFID Tag Password command.

aThe default is 00. The acceptable value range is 00 to FF (hexadecimal).