Overstrike Style

RFID CONTROL Menu Items

Overstrike Style

This menu item selects the style of the overstrike pattern.

The default is Grid.

When it is set to Grid, a grid pattern prints when it overstrikes. When it is set to Error Type Msg, an error message prints that indicates which error occurred (see Table 2).

IMPORTANT If you are using a validator, set the RFID Overstrike Style different than the validator Overstrike Style (in the VALIDATOR menu). This will help you differentiate between an RFID error and a validator error.

Table 2. Printed Overstrike Error Messages

Error Message

Explanation

 

 

 

 

Tag R/W Err x

The printer software attempted to write to or read from the

Check media

RFID tag, but the RFID encoder indicated that the tag could

 

not be written to or read from.

 

 

Tag Comm Err x

The printer software temporarily lost communication with the

Check cable

RFID encoder, or communication between the printer

 

software and the RFID encoder was not synchronized and

 

had to be forced.

 

 

Precheck Fail x

This failure occurs only when the Precheck Tags menu item

Check media

is set to Enable. It indicates that the RFID tag was

 

automatically failed since it did not contain the correct

 

pre-programmed quality code.

 

 

NOTE: The x in the error messages represents a number code that identifies the area in the printer software or RFID encoder where the failure occurred.