Write or Read RFID Format

and uses the value on the control panel’s LCD.

motion Set this flag to 1 to program data into the tag without moving the label. The printer may adjust the label position while it writes data into the tag, but this adjustment will reverse before any subsequent normal label movement. Even if this flag is set to 1, other commands (i.e., alpha or barcode) may move the label.

protect This flag indicates whether the data should be protected from being overwritten later. The default is 0, meaning the data are not protected. Other acceptable values are 1 to 255, meaning the data are protected using this number as the LOCK password.

data format 0 (ASCII) or 1 (hex). The default is 0.

reserved This is a reserved flag. The PPI/ZGL absorbs this number.

Write or Read RFID Format

Purpose This command allows you to write or read to an RFID tag.

Format ^RFa,b,c,d

^RF

Write or Read RFID command.

aSpecifies the read or write option. The default is W.

W = write to the tag L = write with LOCK R = read the tag

bSpecifies the data format. The default is H.

A = ASCII H = Hex

E = EPC format