Table 3. Control Panel Error Messages

Error Message

Explanation

Solution

 

 

 

 

 

 

RFID MAX RETRY

Error Handling = Overstrike in

Press PAUSE to clear the

Check System

the RFID CONTROL menu,

message.

 

and the Label Retry count has

See “Troubleshooting” on

 

been exhausted.

page 70.

 

 

 

RFID TAG ERR:

A write was attempted on a

Press PAUSE to clear the

Read-Only Tag

read-only tag.

message.

 

 

Change media to writable

 

 

tags or remove the write

 

 

command from the

 

 

application.

 

 

 

RFID TAG FAILED

Error Handling = Stop in the

Press PAUSE to clear the

Check Media

RFID CONTROL menu, and

message.

 

the RFID encoder could not

See “Troubleshooting” on

 

read the RFID tag.

page 70.

 

 

 

RFID UNLOCK CMD:

An unlock command was

Press PAUSE to clear the

Not Supported!

executed on a tag which does

message.

 

not support locking.

Remove the unlock

 

 

command from the

 

 

application.

 

 

 

RFID ACS FIELD:

The ACS field was accessed

Press PAUSE to clear the

Not Supported!

on a tag which does not

message.

 

support the ACS field.

Remove references to the

 

 

ACS field from the

 

 

application.

 

 

 

RFID KIL FIELD:

The KIL field was accessed

Press PAUSE to clear the

Not Supported!

on a tag which does not

message.

 

support the KIL field.

Remove references to the

 

 

KIL field from the

 

 

application.

 

 

 

69

Page 69
Image 69
Printronix SL5000r MP manual Rfid MAX Retry, Rfid TAG ERR, Rfid TAG Failed, Rfid Unlock CMD, Rfid ACS Field, Rfid KIL Field