Printronix SL5000r MP manual RPTn, RSTn, RFID PGL Commands

Models: SL5000r MP

1 84
Download 84 pages 51.7 Kb
Page 38
Image 38
RPTn

Chapter 2 RFID PGL Commands

idir

Enter a plus sign (+) or leave the field blank to

 

increment (default). Enter a minus sign (–) to

 

decrement.

step

A decimal number specifies the amount to increment/

 

decrement each time the form is executed. The

 

increment is at bit level and will automatically wrap

 

based on the field size.

RPTn

The optional incremental repeat count parameters to

 

specify the number of times a particular field value is

 

repeated before it is incremented. The default repeat

 

count parameter n is 1, which will increment the field

 

value each time it prints. The repeat count can range

 

from 1 to 65535.

RSTn

The optional incremental reset count parameter to

 

specify the number of times an incremented field is

 

printed before it is reset to the starting value. By

 

default, there is no reset count. The reset count

 

parameter n can range from 1 to 65535.

startdata

Defines the value of the field or the starting value of the

 

incremented field. If the field is dynamic, the value will

 

be specified later in the EXECUTE mode. The data

 

must be specified within a pair of delimiters (D). The

 

delimiter (D) cannot be a “/” or SFCC character since

 

the “/” will comment out the rest of the line and SFCC is

 

reserved for PGL commands. If “R” or “S” is used as

 

delimiters, the data pattern must not comprise of the

 

keywords in the incrementing options. Since the

 

delimiters could be different from one value to another,

 

proper care must be taken to avoid one of the letters

 

mentioned above.

NOTE: 1. The RFWTAG command cannot be mixed with RFWRITE in the same form.

2.Each field structure must be specified in a single line and in the order it appears in the RFID tag from MSB bits to LSB bits (left to right). The sum of all the field lengths must match the size of the tag.

3.The host data are read in as ASCII characters. They would be converted to binary representation for the base

38

Page 38
Image 38
Printronix SL5000r MP manual RPTn, RSTn, RFID PGL Commands