Printronix SL5000r MP manual Return Status Port

Models: SL5000r MP

1 84
Download 84 pages 51.7 Kb
Page 64
Image 64
Chapter 2 Return Status Port

Chapter 2 Return Status Port

Return Status Port

The IGP/PGL VERIFY command (page 48) and PPI/ZGL ^HV command (page 61) require the use of the Return Status port. Set this port using Ret. Status Port in the IGP/PGL SETUP or PPI/ZGL SETUP menu.

NOTE: If you are using the IGP/PGL SETUP menu, you must set Admin User to Enable in the PRINTER CONTROL menu.

If you set Ret. Status Port to Serial, you must set all SERIAL PORT menu settings (i.e., Port Type, Baud Rate, Stop Bits, Parity, etc.) to match the serial port settings in the application.

If you set Ret. Status Port to E-NET Data Port or E-NET Stat Port, you must set the application to connect using TCP/IP. The Host Address must match the IP Address SEG 1 through IP Address SEG 4 settings in the ETHERNET ADDRESS menu. Set the Port Number to 9001 for E-NET Data Port, or 3002 for E-NET Stat Port.

64

Page 64
Image 64
Printronix SL5000r MP manual Return Status Port