Printronix SL5000r MP manual Bit And 96 Bit EPC Data Formats, Class 1 Gen

Models: SL5000r MP

1 84
Download 84 pages 51.7 Kb
Page 73
Image 73
Class 1 Gen 1

Class 1 Gen 1

64 Bit And 96 Bit EPC Data Formats

According to the EPC code standard there are two specific data type formats: 64 bit and 96 bit. The type of format is defined by the first two bits of the EPC Header. When the first two bits are set to 00, the EPC format is interpreted as a 96 bit data format. When the first two bits are not 00, the EPC format is interpreted as a 64 bit data format.

Each tag class handles this situation differently.

Class 1 Gen 1

The original Class 1 Gen 1 tag was a 64 bit memory designed prior to the EPC standard. Therefore despite a newer 96 bit tag, the data dependent indication was ignored. This is true today and therefore as long as the data fits into the tag memory no check is made of its format.

Gen 2

The Gen 2 protocol manages data size differently and does not use the data format to identify the data size. The Protocol Control (PC) bits (a separate entry in the tag) manages the data size. Therefore the data format is not restricted to the EPC data format.

Class 0+, Class Zuma, and Class 1.19

These Classes were developed subsequent to the EPC standard and have 96 bit memories for the EPC code. To distinguish between 64 bit data and 96 bit data, they conform to the EPC code format standard.

Three parameters should match for error free operation:

1.EPC Format

2.Selected Tag Data Length

3.Size of Data Request

73

Page 73
Image 73
Printronix SL5000r MP manual Bit And 96 Bit EPC Data Formats, Class 1 Gen, Class 0+, Class Zuma, and Class