Chapter 5: Configuration

Decoded (Internal) Scanners

Decoded (Internal) Advanced Options

Dot Time (msec)

The value selected for “Dot Time (msec)” determines (in milliseconds) how long the target- ing dot remains on before the scanner switches to a normal scan sweep. When you double- tap on this parameter, a dialog box is displayed in which you can enter a value of 0 msec, 200 msec or 400 msec. A value of 0 (zero) disables the target dot.

Aim Duration

This parameter determines the total time the aiming pattern appears before the scanner laser begins sweeping. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value from 0 to 30 (0 to 3 sec.). A value of 0 (zero) disables the aiming-dot.

Laser On Time

The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed. Double-tapping on this parameter displays a dialog box in which you can enter a value between 5 and 99, each number representing 0.1 seconds.

5.14.2.2Decoded (Internal) Advanced Options

Continuous Scan Mode

Setting this parameter to on keeps the laser on and continuously decoding as long as the scanner button is pressed and held down.

Minimum Cancel Time

The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off.

Low Power Timeout

To extend laser life, you can select the time the scanner remains active following a success- ful decode. The scanner wakes from low power mode when a bar code is scanned—a successful decode restores normal blinking.

This is only used if the unit’s Trigger Mode has been changed to Continuous On. If the Ikôn is used in a fixed mount this parameter might be used, but not if the unit is used as a PDA.

When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec., 1 min., 2 min., or 3 min.

Ikôn Rugged PDA (Windows CE 5.0) User Manual

165

Page 177
Image 177
PYLE Audio 7505-BTSDCMHC25 user manual Dot Time msec, Aim Duration, Laser On Time, Minimum Cancel Time, Low Power Timeout