B. Clearance To Combustibles, UL and ULC

Castile Pellet Insert

R

B. Clearance To Combustibles, UL and ULC

NOTE: All Clearances are Minimum Clearances

AS A BUILT-IN

A

C

D

B

 

B

C

 

 

0 in. Clearance To Exposed Section And Face Trim

Figure 10.1

Must be installed in a non-tapered enclosure.

 

 

 

 

 

 

 

 

 

 

 

 

Inches

Millimeters

 

A

Top of Hopper

Top Vent

2.0

51

 

 

 

 

Rear Vent

2.5

64

 

B

Side of Hopper

Top or Rear Vent

2.0

51

 

C

Back of Hopper

Top or Rear Vent

4.0

102

 

D

Vent Pipe to Combustible

Top or Rear Vent

3.0

76

INSTALLED AS A BUILT-IN UNIT

Shown with Rear Vent and Outside Air

Combustible

12 in

 

Mantel

 

 

(305mm)

 

 

 

6 in

 

Top Vent:

(152mm)

 

2 in. (51mm)

 

 

Rear Vent:

 

 

2.5 in (64mm)

 

 

Back of Hopper:

 

 

4 in (102mm)

 

 

Vent Pipe to

Outside Air

 

Combustibles:

 

 

3 in (76mm)

 

Figure 10.2

AS A BUILT-IN WARNING

Fire Risk.

Comply with all minimum clear- ances to combustibles as speci- fied.

Failure to comply may cause house fire.

NOTE:

Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.