Castile Pellet Insert
R
F. Fire Safety
To provide reasonable fire safety, the following should be given serious consideration:
•Install at least one smoke detector on each fl oor of your home.
•Locate smoke detector away from the heating appliance and close to the sleeping areas.
•Follow the smoke detector manufacturer’s placement and installation instructions and maintain regularly.
H. Inspect Appliance & Components
•Remove appliance and components from packaging and inspect for damage.
•Report to your dealer any parts damaged in shipment.
•Read all the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.
•Conveniently locate a Class A fi re extinguisher to contend with small fi res.
•In the event of a hopper fire:
•Evacute the house immediately.
•Notify fi re department.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
•Installation and use of any damaged appliance.
•Modifi cation of the appliance.
•Installation other than as instructed by Hearth & Home Technologies.
•Installation and/or use of any component part not approved by Hearth & Home Technologies.
•Operating appliance without fully assembling all components.
•Do NOT Overfire.
Or any such action that may cause a fire hazard.
G. Tools And Supplies Needed
Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace:
Reciprocating Saw | Gloves |
Hammer | Safety Glasses |
Phillips Screw driver | Framing Square |
Tape Measure | Electric Drill & Bits) |
Plumb Line | 1/4” |
Level | May also need: |
Framing Material | |
Vent Support Straps | |
Material | Venting Paint |
WARNING
Inspect appliance and components for damage. Damaged parts may impair safe operation.
•Do NOT install damaged components.
•Do NOT install incomplete components.
•Do NOT install substitute components.
Report damaged parts to dealer.
|
|
|
|
|
|
1. |
| Place the appliance in a location near the |
|
| fi nal installation area and follow the proce- |
|
| dures below: |
2. |
| Open the appliance and remove all the parts |
|
| and articles packed inside the Component |
|
| Pack. Inspect all the parts and glass for ship- |
|
| ping damage. Contact your dealer if any irregu- |
|
| larities are noticed. |
3. |
| All safety warnings have been read and fol- |
|
| lowed. |
4. |
| This Owner’s Manual has been read. |
5. |
| Floor protection requirements have been met. |
6. |
| Venting is properly installed. |
7. |
| The proper clearances from the appliance and |
|
| chimney to combustible materials have been |
|
| met. |
8. |
| The masonry chimney is inspected by a profes- |
|
| sional and is clean, or the factory built metal |
|
| chimney is installed according to the manufac- |
|
| turer’s instructions and clearances. |
9. |
| The chimney meets the required minimum |
|
| height. |
10. |
| All labels have been removed from the glass |
|
| door. |
11. |
| Plated surfaces have been wiped clean, if |
|
| applicable. |
12. |
| Thermostat or remote has been installed. |
13. |
| A power outlet is available nearby. |
14. |
| A good quality surge protection is highly recom- |
|
| mended to protect the electronics. |
Page 8 | January 19, 2011 |