Castile Pellet Insert

R

C. Full Reline With Vertical Outside Air

NOTE: Check clearances carefully for this type of installation to ensure adequate room for outside air venting.

12” (305mm) min. above

12” (305mm) min. below

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.

NOTE: In Canada, only a full reline is allowed per ULC S628-93, ORD ULC C1482-M1990.

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as mineral wool or ceramic.

Do not use high temperature caulk- ing materials to seal any edge to prevent future serviceability

Outside Air

Termination

at

Chimney Top

NOTE: In Canada this fi replace insert must be installed with a continous chimney liner a 6 inch (152mm) in diameter extending from the fi replace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirments of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.

Figure 16.1

Page 16

7022-122

January 19, 2011

Page 16
Image 16
Quadra-Fire CASTILEI-MBK owner manual Castile Pellet Insert Full Reline With Vertical Outside Air