Quatech MPAP-100 user manual Receive data and clock signals, Extra clock support for channel A

Models: MPAP-100

1 64
Download 64 pages 37.9 Kb
Page 34
Image 34

The MPAP-100 is a single-channel device. Portions of SCC channel B are used to augment channel A. Channel B cannot be used for transmit, but may be used for receive, subject to certain limitations.

9.4.1Receive data and clock signals

The receive data signals RXDA and RXDB are tied together. The receive clock input signals RTxCA and RTxCB are also tied together. This can be useful in unusual applications. It would be possible to run the receiver and transmitter at different baud rates, using channel B's baud rate generator and receiver for the received data. Of course, the channel A transmitter and receiver can be run at different speeds simply by having external data clocks supplied to TRxCA and RTxCA from the cable.

The W/REQB signal is used to generate DMA requests between the SCC and the external FIFOs if channel B is used for receive.

9.4.2Extra clock support for channel A

The TRxCB clock output can be routed back to RTxCA as another way to use the channel B baud rate generator to derive an independent clock for the channel A receiver. This is controlled by the RCKEN bit in the Communications Register (see page 39).

9.4.3Extra handshaking for channel A

The SCC does not provide a DSR input for either channel. The MPAP-100 routes the DSR signal from the connector to the DCDB input of the SCC. Software can therefore use DCDB as a surrogate for DSR on channel A.

9.4.4Other signals are not used

All channel B signals not listed above are not available at the connector. The CTSB and SYNCB inputs are tied to their inactive states. The TXDB, DTR/REQB, and RTSB outputs are left open.

Page 34
Image 34
Quatech MPAP-100 Receive data and clock signals, Extra clock support for channel A, Extra handshaking for channel A