9.5SCC Incompatibility Warnings

Due to the SCC implementation used by the MPAP-100, there are two minor incompatibilities that the software programmer must avoid.

9.5.1Register Pointer Bits

In a Zilog 85230, the control port register pointer bits can be set in either channel. With the implementation on the MPAP-100, however, both parts of an SCC control port access must use the same I/O address.

 

 

 

IMPORTANT

 

 

 

 

 

 

 

The programmer must be certain not to mix channel usage during

 

 

 

the two-part access of SCC control ports. It would be highly

 

 

 

irregular for code to be written in such fashion, so this restriction is

 

 

 

 

not expected to be burdensome.

 

 

 

 

 

 

 

 

The following sequences will work:

Write Control Port A

(set pointer bits for desired register)

Read or Write Control Port A

(read or write desired channel A register)

Write Control Port B

(set pointer bits for desired register)

Read or Write Control Port B

(read or write desired channel B register)

The following sequences will NOT work:

Write Control Port A

(set pointer bits for desired register)

Read or Write Control Port B

(read or write desired channel B register)

Write Control Port B

(set pointer bits for desired register)

Read or Write Control Port A

(read or write desired channel A register)

9.5.2Software Interrupt Acknowledge

The 85230's software interrupt acknowledge mechanism is not supported. Bit 5 of Write Register 9 (Software INTACK Enable) is forced to 0. Software must employ the "Interrupt Without Acknowledge" interrupt method using Read Registers 2 and 3 to process interrupts.