RayTek FA, FR operating instructions Viewing Angles, Sensor Placement in 2‐Color Mode

Models: FA FR

1 67
Download 67 pages 6.88 Kb
Page 23
Image 23

Sighting hole smaller than the sensor’s field of view

Dirty lens or dirty sighting window

Smoke, steam, dust, gas in atmosphere

Emitted energy

Sensor Location

Emitted energy

Emitted energy

Emitted energy

Target smaller than field of view and/or moves or vibrates in and out of field of view (e.g. wire)

Figure 11: Sensor Placement in 2‐Color Mode

4.7 Viewing Angles

The optical head can be placed at any angle from the target up to 30° for one‐color mode, or 45° for two‐color mode.