RayTek FR, FA operating instructions Multidrop Installation 4‐Wire, Multidrop Installation 2‐Wire

Models: FA FR

1 67
Download 67 pages 6.88 Kb
Page 30
Image 30

Installation

2.Install all electronics wiring according to the applicable sections 5.4, 5.7.x, and 5.8!

3.Plug the RS485/RS232 interface converter into your computer’s serial port, or attach it to a serial cable connected to the computer! Use 9 pin to 25 pin converter if necessary!

4.If the 9 VDC power supply is used, apply power to the RS485/RS232 converter!

5.Apply power to the FA/FR sensor!

6.Turn on your computer!

You need to make sure another serial device (e.g. an internal modem) is not using the identical COM‐port at the same time!

Always make all electrical connections before applying power to the FA/FR sensor! Do not change RS485 or power connections on the RS485/RS232 converter while the FA/FR sensor has power applied, as this may cause damage to the Interface converter!

5.7.1 Multidrop Installation (4‐Wire)

In 4‐wire multidrop installations the data can be transferred in both directions, from sensor to PC and reverse.

 

RS232/485

To Computer

Interface Converter

XXX485CVT…

RS232 serial port

from RxB

 

 

from RxA

 

from TxB

 

from TxA

 

Ground

 

+24 VDC (optional)

9 VDC power supply or ...

24 VDC power supply

Electronics Housing

 

Figure 18: Wiring for 4‐Wire Sensor Setup

5.7.2 Multidrop Installation (2‐Wire)

Using the 2‐wire installation saves 2 wires in comparison to the 4‐wire installation. The disadvantage is, that the data transfer can be only in one direction at the same time.

22

Marathon Series FA/FR

Page 30
Image 30
RayTek FR, FA operating instructions Multidrop Installation 4‐Wire, Multidrop Installation 2‐Wire