OPERATIONS
Options Menu
350-8697 DGy Model 201 User Guide 57
. . . . .
Figure 3-20. System Tab
CHANGING COMMUNICATIONS SETTINGS
In the Network Settings section:
~Fields are provided to report or change (if desired) the
system’s IP address, host name, subnet mask and
default gateway.
~Click Apply to apply the new settings to the DGy 201.
Note that network settings will not be applied to the DGy
201 until the unit has restarted. After you have clicked
on the Apply button you should see a pop up message
window as shown in the following figure (Figure 3-21.)
The Restart warning window gives you the opportunity
to cancel the reboot and go back to the old network
settings, or to restart the DGy 201 using the new
network settings.
Note that WCP will lose communication with DGy 201
as soon as the restart procedure begins. Also, if you
have changed the IP address of DGy 201 you will have
to connect to it using the new network settings. Note
that you will need to restart the WCP from your browser
after the connection has been dropped.