INTRODUCTION
External Timecode Synchronization
350-8697 DGy Model 201 User Guide 10
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EXTERNAL TIMECODE SYNCHRONIZATION
Multi-channel recording requires multiple DGy 201 units to be
synchronized so that start and stop of record and play can be
accomplished. This is achieved by synchronizing the internal real time
clocks of all the DGy 201 units.
All DGy 201 models can be synchronized to an external time source
using a network connection to a NTP (Network Time Protocol) server.
Additionally, the DGy 201 can be configured with an IRIG-B option.
Using the IRIG loop through connection this provides the ability to
synchronize each of the DGy 201 real-time clocks from a single IRIG-B
timecode generator (IRIG DCLS or 1 kHz modulation).