COMMAND LINE INTERFACE
Command Summary
350-8697 DGy Model 201 User Guide 98
. . . . .
. . . . . . . . .
AUDIO COMMANDS A summary of DGy 201 audio commands is listed below. Click on the
hyperlink to see a detailed description of the command. Table 6-5. Audio Commands Summary
Command Description
Sets the sample rate (in kHz) of the audio input
Determines which (if any) audio source is recorded.
Determines whether input sensitivity is appropriate for microphone or line level
signals.
Supplies the low voltage phantom power, required by some electret
microphones.
AUDIO COMMANDS DESCRIPTIONS
The table below lists all DGy 201 audio commands, their arguments and
detailed descriptions.
AUDioFREQuency
AUDioMoDe
AUDioSouRCe
AUDioPHANTom
Table 6-6. Audio Commands
Command Arguments Description
AUDioFREQuency <11.025 | 22.05 | 44.1> Sets the sample rate (in kHz) of the audio input.
Factory default: 44.1 (CD quality).
AUDioMoDe<L | R | Stereo | OFF> Determines which (if any) audio source is recorded.
If AUDioMoDe is set to L or R, the audio is routed to
both output channels on replay.
If AUDioMoDe is set to Stereo, the Left and Right
audio channels are routed independently to the Left
and Right audio output connectors (Stereo or
separate audio).
If AUDioMoDe is set to OFF then audio is not
recorded.
NOTE: This does not affect playback. A clip
containing audio will be replayed independent of
the setting of this command.
Factory Default: OFF
AUDioPHANTom <ON | OFF> Supplies the low voltage phantom power, required
by some electret microphones. The setting of
AUDioPHANTom is ignored unless
AUDioSouRCe is MIC.