Replacing Consumables

RCAUTION:

When accessing the inside of the machine, do not touch any sec- tions other than those specified in this manual. If you do, it might result in receiving a burn or inju- ry.

Important

There are three ozone filters in this printer. Two of them are set inside in the front, one of them is set in the rear. Be careful when replacing the ozone filters as the front side filter is a different shape from the rear side filter.

Disposal can take place at our au- thorized dealer or at appropriate collection sites.

Dispose of used ozone filters as general burnable refuse.

ATurn off the printer's power switch.

BReplace the oil bottle.

BOpen the fuser oil bottle cover of the printer.

TFWX090E

CRemove the used oil bottle

from the printer carefully.

 

4

D Insert the new oil bottle into

 

the oil bottle case.

 

TFWX100E

ARemove the green cap from the new oil bottle.

Important

Hold the clear cap while turning the green cap. Do not remove the clear cap.

TFWX031E

EClose the fuser oil bottle cover.

Important

The fuser oil bottle cover should be kept closed.

CReplace the ozone filter on the back side of the printer.

A Remove

the

ventilator

hole

cover.

 

 

 

 

 

 

TFWX960E