VRS Getting Started Guide
Table 3. Action Types
Action Type | Description |
|
|
Return Error | Pass error (without the image) to the host application. |
|
|
Ignore Error | Accept image "as is," pass it to the host application, and resume the |
| scanning session. |
|
|
Intervention | Open the Auto Resolve Manager in manual mode. As a result, the |
| user is presented a range of options for handling the error. See the |
| next section, Using the Auto Resolve Manager. |
|
|
Auto Resolve | Opens the Auto Resolve Manager in automatic mode. As a result, the |
| scanner automatically attempts to retry the scan until the user |
| resolves an equipment or paper transport impediment, such as a loose |
| cable, paper jam, or out of paper condition. See the next section, Using |
| the Auto Resolve Manager. |
|
|
Interactive | Opens the VRS Interactive Properties dialog box and displays the |
| image in the VRS Viewer, so that the user can apply new settings to |
| the current image. The dialog box opens to the tab that relates to the |
| warning condition. For example, if a Brightness Out of Range |
| warning occurs, the dialog box would open with the focus on the |
| Clarity tab, where the brightness setting can be adjusted. |
|
|
!To define exception condition parameters
1 From the Windows taskbar,
2 From the VRS menu, select Configure to open the VRS Administration Utility dialog box.
3Select one of the following tabs: a Warnings tab
The Warnings tab gives you options to set the threshold and response for exceptions related to image quality, as listed in Table 1 on page 14.
bErrors tab
The Errors tab gives you options to set the response to exceptions related to equipment conflicts and paper transport errors, as listed in Table 2 on page 17.
4Adjust the settings for each tab. a Warnings tab - Threshold
From the Warnings tab, you can type directly into the Threshold box, or click the arrows to select a new threshold setting. For more information about thresholds, see the section Warnings Tab on page 14.
bWarnings tab/Errors tab - Action
From the Warnings tab and the Errors tab, define a VRS response to each exception type by clicking in the Action box and selecting from the
5Once you are satisfied with the settings, click Save.
18 | Kofax Image Products |